Категории

Производители

OMRON 61F-GP-N (-NT-ND-NL) Реле за контрол на ниво

OMRON 61F-GP-N (-NT-ND-NL) Реле за контрол на ниво

  • Тип модул: реле за контрол на ниво 
  • Контролирана величина: ниво на проводяща течност 
  • Захранващо напрежение: 200V AC


Повече информация


180,00 лв с ДДС

48353

30 други артикули от същата категория:

OMRON 61F-GP-N  Floatless Level Switch 

Compact Plug-in Models (11-pin Type)

 

ItemGeneral-purpose 
Controller 
61F-GP-N
High-temperature 
Controller 
61F-GP-NT
Long-distance Controllers 
61F-GP-NL 2KM (for 2 km) 
61F-GP-NL 4KM (for 4 km)
Controlling materials 
and operating 
conditions
For control of 
ordinary purified 
water or sewage 
water
For control of ordinary 
purified water or 
sewage where 
operating ambient 
temperature is high.
For control of ordinary purified water in 
cases where the distance between sewage 
pumps and water tanks or between receiver 
tanks and supply tanks is long or where 
remote control is required.
Supply voltage24, 100, 110, 120, 200, 220, 230 or 240 VAC; 50/60 Hz
Operating voltage range85% to 110% of rated voltage
Interelectrode voltage8 VAC
Interelectrode currentApprox. 1 mA AC max.
Power consumptionApprox. 3.5 VA max.
Interelectrode operate 
resistance
0 to approx. 4 kΩ0 to approx. 4 kΩ0 to approx. 1.3 kΩ (for 2 km) 
0 to approx. 0.5 kΩ (for 4 km)
Interelectrode release 
resistance
Approx. 15 k to ∞ ΩApprox. 15 k to ∞ Ω4 k to ∞ Ω (for 2 km) 
2.5 k to ∞ Ω (for 4 km)
Response timeOperate:80 ms max. 
Release:160 ms max.
Cable length *11 km max.600 m max.2 km max. 
4 km max.
Control output1 A, 250 VAC (Inductive load: cosφ = 0.4) 
3 A, 250 VAC (Resistive load)
Ambient temperatureOperating:-10 to 55°C (-10 to 70°C for high-temperature controller)
Ambient humidityOperating:45% to 85% RH
Insulation resistance 
*2
100 MΩ min. (at 500 VDC)
Dielectric strength *22000 VAC, 50/60 Hz for 1 min.
Life expectancyElectrical: 100,000 operations min. 
Mechanical: 5,000,000 operations min.
WeightApprox. 155 g
AccessoriesHold-down clip PFC-N8

 

 

ItemHigh-sensitivity 
Controller 
61F-GP-NH *4
Low-sensitivity 
Controller 
61F-GP-ND
Two-wire Controller 
61F-GP-NR
Controlling materials 
and operating 
conditions
For control of liquids with 
high specific resistance 
such as distilled water
For control of liquids with low 
specific resistance such as 
salt water, sewage water, acid 
chemicals, alkali chemicals
For control of ordinary purified 
water or sewage water used in 
combination with Two-wire 
Electrode Holder (incorporating 
a resistor of 6.8 kΩ)
Supply voltage24, 100, 110, 120, 200, 220, 230 or 240 VAC; 50/60 Hz
Operating voltage range85% to 110% of rated voltage
Interelectrode voltage8 VAC
Interelectrode currentApprox. 0.12 mA AC max.Approx. 1 mA AC max.
Power consumptionApprox. 3.5 VA max.
Interelectrode operate 
resistance
Approx. 10 kΩ to 
approx. 40 kΩ *3
0 to approx. 1.3 kΩ0 to approx. 2 kΩ
Interelectrode release 
resistance
Approx. 100 k to ∞ ΩApprox. 4 k to ∞ ΩApprox. 15 k to ∞ Ω
Response timeOperate:80 ms max. 
Release:160 ms max.
Cable length *150 m max.1 km max.800 m max.
Control output1 A, 250 VAC (Inductive load: cosφ = 0.4) 
3 A, 250 VAC (Resistive load)
Ambient temperatureOperating:-10 to 55°C (-10 to 70°C for high-temperature controller)
Ambient humidityOperating:45% to 85% RH
Insulation resistance *2100 MΩ min. (at 500 VDC)
Dielectric strength *22000 VAC, 50/60 Hz for 1 min.
Life expectancyElectrical: 100,000 operations min. 
Mechanical: 5,000,000 operations min.
WeightApprox. 155 g
AccessoriesHold-down clip PFC-N8

 

 

*1. The length when using completely insulated, 600-V, 3-conductor (0.75 mm2) cabtire cables. Usable cable lengths will 
       become shorter as the cable diameter or number of conductors becomes larger. For details, refer to Safety 
       Precautions for Floatless Level Controllers. 
*2. The insulation resistance and dielectric strength indicate values between power terminals and Electrode terminals, 
       between power terminals and contact terminals, and between Electrode terminals and contact terminals. For details, 
       refer to Safety Precautions for Floatless Level Controllers. 
*3. Possible to use with 15 kΩ or less, however, this may cause reset failure. 
*4. 61F-GP-NH High-sensitivity Controller uses advanced operation. 
       When the power supply voltage is applied, if there are some liquids between the electrodes (ground and operation 
       electrodes), the internal relay will not operate. 
       When the power supply voltage is applied, if there are no liquids between the electrodes (ground and operation 
       electrodes), the internal relay will operate. 
       If the advanced operation does not satisfy applications, consider using 61F-N8HY controller which uses sequential 
       operation.

 

Compact Plug-in Models (8-pin Type)

 

ItemGeneral-purpose 
Controller 
61F-GP-N8 
61F-GP-N8Y 
*4
Long-distance 
Controllers 
61F-GP-N8L 2KM (for 2 km) 
61F-GP-N8L 4KM (for 4 km)
High-sensitivity 
Controllers 
61F-GP-N8H 
61F-GP-N8HY 
*4
Controlling materials 
and operating 
conditions
For control of ordinary 
purified water or sewage 
water
For control of ordinary purified 
water in cases where the distance 
between sewage pumps and water 
tanks or between receiver tanks 
and supply tanks is long or where 
remote control is required.
For control of liquids with 
high specific resistance 
such as distilled water
Supply voltage24, 100, 110, 120, 200, 220, 230 or 240 VAC; 50/60 Hz
Operating voltage range85% to 110% of rated voltage
Interelectrode voltage8 VAC24 VAC
Interelectrode currentApprox. 1 mA AC max.Approx. 0.4 mA AC max.
Power consumptionApprox. 3.5 VA max.
Interelectrode operate 
resistance
0 to approx. 4 kΩ0 to 1.3 kΩ (for 2 km) 
0 to 0.5 kΩ (for 4 km)
Approx. 15 kΩ to 
approx. 70 kΩ *3
Interelectrode release 
resistance
Approx. 15 k to ∞ Ω4 k to ∞ Ω (for 2 km) 
2.5 k to ∞ Ω (for 4 km)
Approx. 300 k to ∞ Ω
Response timeOperate: 80 ms max. 
Release: 160 ms max.
Cable length *11 km max.2 km max. 
4 km max.
50 m max.
Control output1 A, 250 VAC (Inductive load: cosφ = 0.4) 
3 A, 250 VAC (Resistive load)
Ambient temperatureOperating: -10 to 55°C
Ambient humidityOperating: 45% to 85% RH
Insulation resistance *2100 MΩ min. (at 500 VDC)
Dielectric strength *22000 VAC, 50/60 Hz for 1 min.
Life expectancyElectrical: 100,000 operations min. 
Mechanical: 5,000,000 operations min.
WeightApprox. 155 g
AccessoriesHold-down clip PFC-N8

 

 

ItemLow-sensitivity 
Controller 
61F-GP-N8D
Two-wire Controller 
61F-GP-N8R
Variable Sensitivity Controller 
61F-GP-N8-V50
Controlling materials 
and operating 
conditions
For control of liquids 
with low specific 
resistance such as salt
water, sewage water, 
acid chemicals, alkali 
chemicals
For control of ordinary 
purified water or sewage 
water used in combination
with Two-wire Electrode 
Holder (incorporating a 
resistor of 6.8 kΩ)
For control of cases where variable 
sensitivity control is required such as 
detection of froth on the surface of a 
liquid, control of soil moisture content,
or detection of degree of water 
pollution
Supply voltage24, 100, 110, 120, 200, 220, 230 or 240 VAC; 
50/60 Hz
24, 110, 220 or 240 VAC; 50/60 Hz
Operating voltage range85% to 110% of rated voltage
Interelectrode voltage8 VAC24 VAC
Interelectrode currentApprox. 1 mA AC max.Approx. 3 mA AC max.
Power consumptionApprox. 3.5 VA max.
Interelectrode operate 
resistance
0 to approx. 1.3 kΩ0 to approx. 2 kΩ0 to 50 kΩ (Variable)
Interelectrode release 
resistance
Approx. 4 k to ∞ ΩApprox. 15 k to ∞ ΩOperating resistance +50 kΩ max.
Response timeOperate: 80 ms max. 
Release: 160 ms max.
Cable length *11 km max.800 m max.50 m max.
Control output1 A, 250 VAC (Inductive load: cosφ = 0.4) 
3 A, 250 VAC (Resistive load)
Ambient temperatureOperating: -10 to 55°C
Ambient humidityOperating: 45% to 85% RH
Insulation resistance *2100 MΩ min. (at 500 VDC)
Dielectric strength *22000 VAC, 50/60 Hz for 1 min.
Life expectancyElectrical: 100,000 operations min. 
Mechanical: 5,000,000 operations min.
WeightApprox. 155 g
AccessoriesHold-down clip PFC-N8

 

 

*1. The length when using completely-insulated, 600-V, 3-conductor (0.75 mm2) cabtire cables. Usable cable lengths will 
       become shorter as the cable diameter or number of conductors becomes larger. 
*2. The insulation resistance and dielectric strength indicate values between power terminals and Electrode terminals, 
       between power terminals and contact terminals, and between Electrode terminals and contact terminals. 
*3. Possible to use with 15 kΩ or less, however, this may cause reset failure. 
*4. 61F-GP-N8H/-N8Y High-sensitivity Controllers use advanced operation. 
       When the power supply voltage is applied, if there are some liquids between the electrodes (ground and operation 
       electrodes), the internal relay will not operate. 
       When the power supply voltage is applied, if there are no liquids between the electrodes (ground and operation 
       electrodes), the internal relay will operate. 
       If the advanced operation does not satisfy applications, consider using 61F-N8HY controller which uses sequential 
       operation.

Количка  

Няма продукти

Доставка 0,00 лв
Сума 0,00 лв

Количка Поръчай

Нови продукти

  • 10K 1W ±5% Резистор
  • 3K 0.6W ±1% Резистор
10K 1W ±5% Резистор
10K/1W ±5% РезисторТип на резистора: TC300... >>
3K 0.6W ±1% Резистор
3K/0.6W ±1% РезисторТип на резистора: TC50... >>
1.8 Ohm 0.6W ±1% MF0207FTE52-1R8 Резистор Металослоен
MF0207FTE52-1R8 1.8 Ohm/0.6W ±1% 50ppm резистор... >>
1.5 Mohm 0.25W ±1% Резистор
1.5 Mohm/0.25W ±1% РезисторТип на... >>
052-005-0150 ДИОДНО ТЯЛО SMD LED 150СМ 72W 6400K IP20 TETRA/SQ-72
052-005-0150 светодиодно тяло SMD LED 150cm 72W... >>
MSQ-30/40 50/5A Токов трансформатор
MSQ-30/40 50/5A Токов трансформаторМодел:... >>
TESA Изолирбанд зелен/жълт Tesaflex 53988-00081-00 19mmX20m
Електроизолационна лента 20m x 19mm зелен/жълт... >>
FZT558TA
FZT 558 TA - Транзистор: PNP; биполярен; 400V;... >>
1 Mohm 1W ±1% Резистор
1 Mohm/1W ±1% РезисторТип на резистора:... >>
ТРАНСФОРМАТОР HAHN BV EI 304 2899 12V 2.1VA
ТРАНСФОРМАТОР HAHN BV EI 304 2899 12V 2.1VA... >>
ТРАНСФОРМАТОР HAHN BV EI 304 2082 12V 2.1VA
ТРАНСФОРМАТОР HAHN BV EI 304 2082 12V 2.1VA PCB... >>
TESA Универсална двойно лепяща лента 50m x 12mm
TESA Универсална двойно лепяща прозрачна... >>
ТРАНСФОРМАТОР ТОРОИДАЛЕН 20V 36VA
ТРАНСФОРМАТОР ТОРОИДАЛЕН 20V 36VAТип... >>
ТРАНСФОРМАТОР ТОРОИДАЛЕН 20V+24V 170VA
ТРАНСФОРМАТОР ТОРОИДАЛЕН 20V+24V 170VA... >>
ТРАНСФОРМАТОР ТОРОИДАЛЕН 12V+20V 105VA
ТРАНСФОРМАТОР ТОРОИДАЛЕН TOREL 12V+20V 105VA... >>
ТРАНСФОРМАТОР ТОРОИДАЛЕН TT-600-01-TRF-CDR CODICE 4270100 600VA
ТРАНСФОРМАТОР ТОРОИДАЛЕН TT-600-01-TRF-CDR... >>
ТРАНСФОРМАТОР ТОРОИДАЛЕН TRFPJ1KTRFT / RVR14/3 1500VA
ТРАНСФОРМАТОР ТОРОИДАЛЕН TRFPJ1KTRFT / RVR14/3... >>
H06-01 SMC
H06-01 SMC Hexagonal male rectum - H FITTING,... >>
FESTO QS-1/2-10-I
FESTO QS-1/2-10-I Push-in fitting Festo code:... >>
470K 0.25W ±5% Резистор
470K/0.25W ±5% РезисторТип на резистора:... >>

Всички нови продукти