Non-Contact Pneumatic Sensors. Logic Components for Sensor Output Signals
These elements amplify and process output signals from pneumatic sensors
with pressures of 0.02 to 3.8 psi / 0.001 to 0.25 bar.
Each element is factory-mounted on a 2n width mounting plate.
Function:
Type ZK-2-R-M5
AND logic amplification element for pneumatic sensors. An output is present at
A if both X and Y are present.
Type OS-2-R-M5
OR logic amplification element for pneumatic sensors. An output is present at
A if either X or Y is present.
Type VLO-R-M5
Logic amplification element for pneumatic sensors. An output is present at A if
X is present and Y is NOT present.
Type VK-R-M5
Amplifier element for pneumatic sensors with two-stage amplification. An
output is present at A if X is present.
For the sub-base, internal connections are accomplished by means of
integrated air channels.
Signal inputs X and Y of the four elements are supplied with low pressure
(sensor output signals). The output at A is a high pressure signal (supplied by
PH).
An air pressure supply of 15 to 105 psi / 1 to 7 bar is required at PH. An
additional air pressure supply of 1.5 to 3.8 psi / 0.1 to 0.25 bar is required at
connection PN.